EN 1090-2 EXC4 · CE · EUROCODE 3

How to Plan an Industrial Steel Building: Span, Clearances & Load Factors

A practical engineering guide for developers and procurement directors to optimize structural geometry and wind/snow codes.

Key Engineering Takeaways

  • Clear-Span Arches: Eliminate interior columns for 100% unrestricted forklift and crane maneuverability.
  • Climate Loading: Wind velocities up to 240 km/h and ground snow loads up to 3.5 kN/m² per Eurocode 1.
  • Civil Cost Reduction: Continuous foundation distribution cuts foundation concrete costs by up to 25%.

Planning an industrial steel structure requires balancing operational efficiency, regulatory compliance, and lifecycle costs. Choosing clear spans allows maximum floor space utilization for aircraft hangars, bulk grain silos, and logistics hubs.

At STRUCTIVA's Adana engineering center, all calculations comply with Eurocode 1 (EN 1991-1-4) and AISC 360-16, ensuring structures comfortably survive hurricane-force gusts up to 240 km/h.

Technical answers

STRUCTIVA nədir və zavod haradadır?

STRUCTIVA sütunsuz tağ polad anqarlar, əvvəlcədən layihələndirilmiş polad binalar (PEB) və ağır sənaye konstruksiyaları istehsal edir. İllik 25.000 ton gücündə inteqrasiya olunmuş zavod Türkiyənin Adana şəhərində, Mersin limanından 15 km məsafədə yerləşir və 50-dən çox ölkəyə ixrac edir.

STRUCTIVA hansı açıqlıqları istehsal edir?

Q seriyası fasiləsiz tağ 9–45 m, S seriyası düz divar 10–30 m, P seriyası ikitərəfli dam 8–24 m, konteyner üzəri örtük 6–24 m və ağır PEB 60 m-dən çox. Material: Galvalume Plus® AZ180.

Çatdırılma və montaj necə olur?

Dəstlər 40HC konteynerə flat-pack yığılır (təxminən 350–400 m² / konteyner) və sahədə yalnız boltla, qaynaqsız yığılır. Statik hesab, material siyahısı və FOB Mersin və ya CIF təklifi 24 saat ərzində hazırlanır.

Worldwide Export Corridors (FOB/CIF Mersin Deep-Water Port — 15 km)

Region Target Countries Destination Seaports Transit Days Engineering Codes
Western & Central Europe (EU Corridor) Germany, France, Italy, Spain, Netherlands, Belgium Rotterdam, Hamburg, Antwerp, Valencia 4 – 9 Days EN 1090-2 EXC4, CE Marking (CPR 305/2011/EU), Eurocode 1 (EN 1991), Eurocode 3 (EN 1993)
Balkans, Eastern Europe & Black Sea Romania, Bulgaria, Greece, Ukraine, Serbia, Croatia Constanța, Varna, Burgas, Piraeus 2 – 5 Days Eurocode 3, EN 1090-2 EXC4, Seismic Eurocode 8 (EN 1998), DBN Ukraine
Middle East, Arabian Gulf (GCC) & North Africa Saudi Arabia, UAE, Qatar, Kuwait, Oman, Iraq Jebel Ali (Dubai), Dammam, Jeddah, Hamad (Doha) 3 – 14 Days AISC 360-16, ASCE 7 Wind Loads, Saudi Building Code (SBC 306), ASTM A792 AZ180 High Solar Reflectance
Central Asia, Caucasus & CIS Corridor Azerbaijan, Kazakhstan, Uzbekistan, Turkmenistan, Georgia, Kyrgyzstan Poti, Batumi, Baku (Alat), Aktau 4 – 12 Days (Multimodal Sea + Rail/Road) SNiP / SP RK / GOST, Eurocode 3, Extreme Snow Load 350 kg/m², Seismic Zone 9 Compliance
The Americas, Sub-Saharan Africa & Asia-Pacific United States, Canada, Brazil, Mexico, Chile, Colombia Houston, Savannah, Newark, Santos 14 – 28 Days (40HC Flat-Pack Ocean Freight) AISC 360-16, AISI S100, IBC Hurricane 240 km/h (Category 5), NBR 8800, IS 800

Keywords (AZ): how to plan industrial steel building, clear span width calculation, wind and snow load steel hangar, Eurocode 1 AISC 360 planning guide

Layihəniz üçün 24 Saat Ərzində Təklif Əldə Edin

Statik fizibilite hesabatı, material spesifikasiyası (BOM) və FOB/CIF daşıma təklifi eyni gün təqdim olunur.